AC Three Phase Measurement
Input Current: 5A/1A by CTs
THD with 2-31st Harmonics
72*72mm
Ture RNS Measurement
4DI & 2DO
Pulse Output
AC Three Phase Measurement
Input Current: 5A/1A by CTs
THD with 2-31st Harmonics
72*72mm
Ture RNS Measurement
4DI & 2DO
Pulse Output
7-inch Touch-Screen
Receive Max. 240 Sensors
Work with SCADA System
Electrical parameter measurement :U,I,f,P,Q,PF,Ep,Eq,Es[50/51] Overcurrent , 3stages;
[50N/51N]Zero-sequence overcurrent protection (3 stages earth fault);[59] Over voltage protection;[27] Under voltage protection;[81U] Under frequency;[26/63] Non-electricity protection;[79] Auto-reclose;
Application scenario: Municipal construction, hospitals, schools, hotels, commercial buildings, etc.;
Installation method: Embedded installation, snap fixing.
Input:DC0~500A
Ouput:DC 4~20mA
Power Supply:DC12V/24V
Application:Solar,Energy storage , Wind energy, UPS, BMS, EV charging pile
Smart Gateway
Data Tranfer Unit (DTU)
WIFI Communication
CE Certificated
Downstream RS485 Communication
Max. Access 25 Devices
Rated Current: 80A Direct Input
Bulit-in Relay
For Prepaid/Postpaid Billing System
Wireless 4G Communication Optional
RS485 Communication
8 Channels Temperature Measurement
Support PT100/Thermocouple Sensors
High Accuracy Class 0.5
2 Channels Alarm output
RS485 Communication
6 Channels NTC cable
Class 1
Sampling frequency: 1-240s
-40℃~150℃ Temperature Range
Wireless distance: 1000m in open space
Support Modbus Protocol
35mm DIN Rail Mounted
Extend battery pack life
Early warning and battery equalization
For UPS Monitoring/Data Center
SOC SOH Monitoring
Reliable and stable long-term operation
Support Modbus Protocol
Tie-down mounting or adhesive mounting
High anti-interference design
for UPS Monitoring/Data Center
SOC SOH Monitoring
Real-time data display
Charging/Discharging records
Basic information management functions
Group batteries SOC, SOH estimation
Regular inspection
Indicator light
Solid Core
High Accuracy Class 0.5
IEC/EN61869-1;IEC/EN61869-2;CE
Horizontal square hole type
Application: Busbar,Cables. New construction projects
Solid Core
High Accuracy Class 0.5
IEC/EN61869-1;IEC/EN61869-2;CE
Vertical square hole type
Application: Busbar,Cables. New construction projects
Wireless Comm. LoRaWAN EU868MHz
Input Current 5A by CTs
868/915/923/470/433MHz LoRaWAN
35mm DIN Rail Mounted
4 Modules 72mm Width
CE Certificated
For IoT Energy Management, Factory, School
One Channel Temperature & Humidity Measurement
Measuring temperature range: -40~+99℃
Measuring temperature range: 20%RH~90%RH
Display: LED display
RS485(Modbus-RTU) Communication
One Channel Temperature & Humidity Measurement
Measuring temperature range: -40~+99℃
Measuring temperature range: 20%RH~90%RH
Display: LED display
RS485(Modbus-RTU) Communication
Three Channel Temperature & Humidity Measurement
Measuring temperature range: -40~+99℃
Measuring temperature range: 20%RH~90%RH
Display: LED display
RS485(Modbus-RTU) Communication
Multi-Circuits Measurement
Max. 4 Channels Three Phase or 12 Channels Single Phase
Ethernet Communication Optional
Modbus TCP Protocol
CE Certificated
RS485 Communication
Application: Base station
Founded in 2003, Acrel Co., Ltd.【Stock Code: 300286.SZ】 is a high-tech enterprise specializing in energy management solutions and electrical safety. Headquartered in Shanghai, Acrel offers innovative and sustainable solutions for microgrid energy efficiency and electrical safety. With over 600 patents and software copyrights, Acrel has deployed more than 28,000 system solutions globally, forming a comprehensive "cloud-edge-end" energy internet architecture.
Acrel Co., Ltd. is China
Digital Energy Meters Company and
Electricity Energy Meters Suppliers. Acrel's integrated product ecosystem spans from cloud platform software to end-user components, covering sectors such as power, renewable energy, data centers, smart buildings, transportation, and smart cities. These solutions enable intelligent, real-time energy management, enhancing energy security and reducing operational costs. We offer
Power Monitoring and Measurement Device for sale.
The company's production facility, Jiangsu Acrel Electric Manufacturing Co., Ltd., adheres to strict quality standards and environmental guidelines, with advanced testing centers and a commitment to lead-free production processes. Acrel's team of over 500 engineers delivers cutting-edge energy efficiency systems and smart energy solutions.
With a strong domestic presence, Acrel is actively expanding internationally, supported by a global network of sales and technical teams and an e-commerce platform that ensures seamless service experiences worldwide. Acrel is proud to help businesses improve efficiency, reduce consumption, and achieve sustainability goals.
Together, we are building a smarter, greener future.
Authorized Patents
0+Number of Customers Served
0+Total Employees
0+Manufacturing Base
0m²Why Knowing Your Meter Location Matters Every property that draws power from the grid has a dedicated energy meter tracking how much electricity flows into the building. For most ...
Read MoreEvery electricity bill lists a number followed by “kWh” — but what does it truly represent? In energy metering, a unit of energy typically used for metering is the kilowatt-hour....
Read MoreCurrent transformers are among the most precisely engineered components in power measurement and protection systems. Yet their internal structure is rarely examined in detail. Und...
Read MoreEvery time a household appliance runs, a factory machine operates, or a commercial building draws power from the grid, an invisible process of measurement takes place in real time...
Read MoreSignal Conditioning: The scaled-down analog signals from the sensors are passed through filters to remove noise and then fed into an Analog-to-Digital Converter (ADC).
Digital Conversion: The ADC converts the continuous analog signals (sine waves) into discrete digital values that a microprocessor can understand.
Computation: This is the core of the device. The microprocessor, following predefined algorithms, performs calculations on these digital values. The most basic calculation is active energy (kWh), which is the integral of power (voltage * current) over time. Modern meters also calculate:
Reactive Energy (kVARh): Crucial for understanding inefficient power use in inductive loads like motors.
Apparent Energy (kVAh): The vector sum of active and reactive power.
Power Factor (PF): The ratio of active power to apparent power, a key indicator of efficiency.
Harmonic Distortion: Measurement of unwanted frequencies on the electrical waveform caused by non-linear loads like computers and LED lights.
Real-time Power Quality Analysis: Monitoring voltage sags, swells, transients, and frequency variations that can damage sensitive equipment.
Load Profiling: Creating detailed charts of energy usage patterns over time to identify waste and opportunities for optimization.
Demand Monitoring: Tracking the maximum power (kW) used in a specific interval, which is a critical factor for commercial and industrial electricity bills.
Predictive Maintenance: By analyzing energy consumption patterns, these systems can detect anomalies that signal impending equipment failure, allowing for maintenance before a costly breakdown occurs.